Sensor Calibrate in Olivetti PR2/PR2E Passbook Printer

While try to print on passbook, after giving print command from pc. Passbook gets ejecting automatically.
Ready ,Station1, Station2 led’s blinking continuously.

Issues with

Occurrence of some microscopic particles of solid matter on Photo sensors of passbook printer.

Procedure to Calibrate Sensor

1) Switch off the printer.
2) Open the top cover of the printer and keep Head of printer at extreme right side.
           a. Press all three buttons ("Station 1", "Local" and "Station 2") and then switch on the printer.
           b. Printer will give a beep sound.

3) Then manually drag the print head from right side to extreme left side
4) Now close the top cover of the printer and press "Station 1" two times.
          a. The print Head will start moving and roller will start rolling.

5) Add a paper to the printer, Printer gives the action of sucking, but wont suck the paper.
          a. By this process, photo sensors gets cleaned

6) Now press "Station 2" once and then add a paper to the printer.
7) Calibration print out will come successfully.
8) Switch off the printer and gets switched on.
9) Ready led will glow and the printer is in ready condition.

Note: Calibrating a printer is not an easy task and you may do these steps three-four times to calibrate the printer properly